Disyuntor de tanque SF6 de alto voltaje para exteriores de 126KV 1600A

Disyuntor de tanque SF6 de alto voltaje para exteriores de 126KV 1600A

The 126KV 1600A Outdoor high-voltage SF6 tank circuit breaker is a sophisticated electrical switching solution designed to safely disconnect high-voltage electrical paths in emergency situations or for regular maintenance. It employs sulfur hexafluoride (SF6) gas as a fire-suppressing and insulating agent, housed within a hermetically sealed container. This particular type of circuit breaker is purpose-built for exterior installation in electrical substations and power distribution systems.

Leer másEnviar Consulta
Disyuntor de tanque de alto voltaje SF6 para exteriores de 72,5 KV y 1600 amperios

Disyuntor de tanque de alto voltaje SF6 para exteriores de 72,5 KV y 1600 amperios

The 72.5KV 1600amp Outdoor SF6 high-voltage tank circuit breaker is a unique electrical switch used to disrupt high-voltage electric circuits when faults occur or for regular switching tasks. It relies on sulfur hexafluoride (SF6) gas enclosed in a sealed tank to extinguish arcs and provide insulation. This particular circuit breaker is specially designed for outdoor placement in electrical substations and power distribution systems.

Leer másEnviar Consulta
Disyuntor de tanque SF6 de alto voltaje para exteriores 40.5KV 1600A

Disyuntor de tanque SF6 de alto voltaje para exteriores 40.5KV 1600A

The 40.5KV 1600A Outdoor high-voltage SF6 tank circuit breaker is a customized electrical switchgear designed to disconnect high-voltage electrical paths in emergency situations or for scheduled maintenance. It employs sulfur hexafluoride (SF6) gas as the medium to extinguish electrical arcs and provide insulation, which is safely confined within a sealed enclosure. This particular type of circuit breaker is purposely designed for exterior deployment in electrical substations and power transmission systems.

Leer másEnviar Consulta
Disyuntor de media tensión exterior sf6 de 24KV 1250A

Disyuntor de media tensión exterior sf6 de 24KV 1250A

The 24KV 1250A outdoor sf6 medium voltage circuit breaker is designed for controlling and protecting 24KV transmission and transformation systems, operating at 50Hz and suitable for outdoor use. Additionally, it can function as a connecting circuit breaker and an integrated opening and closing device. This circuit breaker employs an intelligent arc-quenching system based on thermal expansion and auxiliary blowing, paired with a CT10 spring operating mechanism. Furthermore, it meets the standards set by GB/T1984-2014 for AC high-voltage circuit breakers and adheres to the IEC62271-100:2001 international standard for high-voltage AC circuit breakers and control equipment.

Leer másEnviar Consulta
Interruptor de aislamiento de dos postes con rotura vertical de 12KV 1250AMP

Interruptor de aislamiento de dos postes con rotura vertical de 12KV 1250AMP

The 12KV 1250AMP Vertical break two post isolating switch is specifically designed for use in 10(12,15,24)KV high voltage transmission and distribution lines. These switches serve the purpose of disconnecting and connecting single-phase or three-phase circuits without load and voltage. They are particularly engineered for single-phase application within a three-phase circuit system and are characterized by a simple and cost-effective design, ensuring ease of operation and maintenance. The switches are available in a range of rated current options, including 200400,600,630,800, and 1000,1250 amperes, providing the flexibility to select the most suitable option based on specific requirements. They are comprised of a base, pillar insulator, conductive part, and mechanism part.

Leer másEnviar Consulta
Interruptor de aislamiento de dos postes con rotura vertical de 11KV y 2000 amperios

Interruptor de aislamiento de dos postes con rotura vertical de 11KV y 2000 amperios

The 11KV 2000amp Vertical break two post isolating switch is a composite-structured 12KV switch designed for outdoor line networks. Equipped with a CS-type operating mechanism, it effectively prevents incorrect operations, such as interlocking with live conductors and composite flash-locks. This negates the necessity for an additional earthline, providing a convenient and efficient solution. Furthermore, the pollution-proof isolating switch is particularly well-suited for use in heavily contaminated areas, effectively addressing shed pollution during operation and ensuring a clean and safe working environment.

Leer másEnviar Consulta
Seccionador de tierra 145KV 3150A

Seccionador de tierra 145KV 3150A

145KV 3150A Earthing switch,The neutral point serves various functions, contributing to distinct technical characteristics and operational requirements. The BJ-type transformer neutral point gap grounding protection device plays a crucial role in preserving operational reliability, equipment insulation, and protective measures to ensure consistent performance.

Leer másEnviar Consulta
Seccionador de punto neutro 126KV 1250A

Seccionador de punto neutro 126KV 1250A

126KV 1250A Neutral point disconneetor is specifically engineered for application in high-voltage transmission lines operating under no-load conditions. Its primary function is to provide electrical isolation during the maintenance of circuit breakers and other associated equipment, thereby ensuring compliance with insulation distance requirements and enhancing overall operational safety.

Leer másEnviar Consulta
En China, Shanghai Fato Group Co., Ltd. El proveedor se especializa en Componentes. Como uno de los principales fabricantes y proveedores en China, proporcionamos una lista de precios si lo desea. Puede comprar nuestra alta calidad y personalizada Componentes de nuestra fábrica. ¡Esperamos sinceramente convertirnos en su socio comercial confiable a largo plazo!